Flow Meter Analogue Converter: Summary
This simple wall, or in some cases, flowmeter mounted analogue converter instrument gives an analogue output proportional to flow. Three basic models are available offering 0/4 to 20mA,
0 to 5 volt and 0 to 10 volt outputs. In all cases the offset and full scale adjustments are independent of each other. The standard converter has an input frequency range of 0.5 to 850Hz. This is selectable via DIL switches. A special lower range version is available for use with lower frequency inputs such as positive displacement flowmeters, this device operates down to 0.25Hz.
At these very low frequencies the output can be 'damped'. Two status LEDs indicate whether pulses are being received and if the output is operating within its selected flow range. The enclosure is a high impact polymer that seals the unit to IP65 (NEMA 4X). Access to the terminals is via a pair of glands on the bottom of the enclosure.of glands on the bottom.

Analogue Converter for Flow Meters
Analogue Converter For Flow Meters: Features
- 0/4-20mA, 0-5V or 0-10V
- IP65 (Nema 4X)
- Non volatile memory
- 15-24V dc operation
- Pulse input
- Output damping
- 0 – 50°C
- Competitively priced
- Wall mounting
- 4 frequency ranges
- Sensor PSU (5V)
- Separate zero & span adjustments
- Pulse input indicator
- Output status LED
The Titan Analogue Converter for Flow Meters is Ideal for:
- Data monitoring
- Test rigs
- Control systems

Analogue Converter for Flow Meters
Analogue Converter for Flowmeters: Specification
Power
15 – 24 V dc
Output
0/4 to 20mA
0 to 5 Vdc
0 to 10 V dc
Signal
Pulse input compatible with reed switch, Hall effect or optical detectors
Display
Status LEDs
Red for output errors
Green for signal input.
Enclosure
IP66 (NEMA 4X) High impact glass polymer.
Temp
0°C to +50°C.
Frequency range
0.25/0.5 – 850Hz. Selectable. In four ranges. Output damping for low frequencies
Sensor Supply
5 volts regulated up to 50mA
Weight
0.162 kg
Flow Meter Analogue converter – Order codes
- 370-005 0/4-20mA
- 370-006 0-10V
- 370-007 0-5V
- *For operation down to 0.25Hz insert suffix V4 after the above part numbers, E.g. 370-005V4
Flow Meter Analogue converter: Standard Materials of construction
UV resistant polycarbonate case, stainless steel screws.
Analogue converter For Flow Meters: Dimensions & Mounting

Flow Meter Analogue Converter

Analogue Converter for Flow Meters
Calibrating the Titan ‘Flowmeter Analogue Converter ‘
As with nearly all of our products calibration is performed for you at our factory on equipment that has traceable calibrations to national standards. If for any reason the analogue converter requires re-calibration in situ the following procedure may be followed.
1. Select from the chart below the anticipated operating range for the converter.
2. With no pulse input (or your minimum) set the zero flow output. This may be 0 volts, 0mA or 4mA depending on the requirements.
3. Set the flow to your maximum or inject a frequency equivalent to this and adjust the span potentiometer to give your required full scale.
4. If the output LED shows an over or under range status select the next frequency range up or down and start again.
Frq. Range | Sw1 | Sw2 | Sw3 | Sw4 |
5-25 Hz 20-80 Hz 70-245 Hz 225-850 Hz | off on off off | off off on on | off off off off | off off off off |
For low frequency use, Sw4 on reduces output jitter |
Please submit your details in order to gain access to the download:
Privacy Statement

Analogue Converter for Flow Meters
Flow Meter Analogue Converter: Order Codes

Analogue Converter for Flow Meters
370-005 0/4-20mA
370-006 0-10V
370-007 0-5V
*For operation down to 0.25Hz insert suffix V4 after the above part numbers, E.g. 370-005V4