FT2 Turbine Flow Meter: SummaryFT2 Turbine Flow Meter: FeaturesSTP File Download (3D File)FT2 Turbine Flow Meter: Overview (PDF download)FT2 Turbine Flow Meter: Instruction Sheet (PDF download)FT2 Turbine Flow Meter: ImagesFT2 Turbine Flow Meter: Order Codes

FT2 Turbine Flow Meter: Hall-Effect Detection

This multi-range radial flow turbine flow meter, the FT2 hall-effect turbine flow meter uses a low inertia turbine supported on robust sapphire bearings, in a chemically resistant housing. Nine flow ranges (0.05 to 160 litres per minute), a choice of “plug in” fittings and individual traceable calibration make this meter one of the most flexible available. This Turbine flow meter uses Hall Effect sensing so that opaque fluids may still be metered. For OEM applications the fittings can be tailored to suit the installation and speed up production. Custom leads or connectors are also available for quantity orders.

FT2 turbine flow meter with various PVC fittings

FT2 turbine flow meter with various PVC fittings

FT2 Turbine Flow Meter: Hall-Effect Detection

At the heart of the FT2 hall effect turbine flow meter is a precision turbine that rotates freely on robust sapphire bearings. This rotation is detected by a Hall Effect detector. The resulting output is a NPN pulse that is readily interfaced with most electronic display or recording devices. This combination of materials and technology ensures a long life product with reliable operation throughout. Because this hall effect turbine flowmeter is so versatile with respect to flow range and fittings every combination of range and fitting is not available. The chart below shows the maximum standard flow rate/fitting we would recommend to attain our performance figures. Alternatives are possible but there would be degradation in the turbine flow meter’s performance.

  • Hall effect turbine flow meter
  • Economical
  • PPS body
  • ± 0.75% reading *
  • 1-2% FSD
  • Sapphire bearings
  • Hall-Effect sensing
  • 9 Flow ranges
  • Pulse output
  • 15 Bar rating
  • IP65
  • Viton® seal as standard
  • Choice of fittings
  • 0.1% Repeatability
  • 5 to 24 V dc
  • -15°C Min to 125°C Max
    * When used with our Metra-smart instrument

Tthe FT2 Hall Effect Turbine Flow Meter is Ideal for:

    • Opaque fluids
    • Laboratory tests
    • Cooling equipment
    • Semiconductor plant
    • Water treatment
    • Low viscosity fluids
Group shot of FT2 turbine flow meter manufactured in stainless steel with s/s fittings

Group shot of FT2 turbine flow meter manufactured in stainless steel with s/s fittings


FT2 Turbine Flow Meter: Hall-Effect Detection – Standard Materials of Construction

  • Body – PPS
  • 'O' Ring Seal – Viton®
  • Bearings – Sapphire
  • End fittings – PVDF, PVC, St St, Brass
  • Magnet – Over-moulded

titan ft2 turbine flow meter fittings diagram

Titan FT2 Turbine Flow Meter: Fittings


FT2 Turbine Flow Meter (Hall-Effect Detection)

#Order code

004
016
045
065
010
030
060
100
160

Flow range
L/Min

0·05 – 0·5
0·12 – 1·6
0·13 – 4·5
0·25 – 6·5
0·60 – 10
2.50 – 30
5.00 – 60
6.00 – 100
10.00 – 160
Linearity
% FSD

2.0
1.5
1.5
1.0
1.0
1.5
1.5
2.0
1.5
Typical
Freq. Hz.

133
207
318
260
218
275
275
275
320
Approx
‘K’ Factor

16000
7700
4250
2400
1250
550
275
165
120

 

Fitting Recommended Max flow L/Min PVC PVDF Brass 316 St St
8mm hose 4.5 *
13mm hose 10 *
¼' BSP female 4.5 * *
½' BSP male 30 * * *
¾' BSP male 100 * * * *
1' BSP male 160 * * *

Please submit your details in order to gain access to the download:
Privacy Statement

*Your personal information will only be used as set out in the Titan Enterprises privacy policy. Submitting your details indicates your agreement to our privacy policy and consent, for the time being, that we may contact you about products and services that will be of interest to you via e-mail. It’s your choice, you can opt-out at ANY time. Just click the unsubscribe link at the bottom of any of our emails to tell us your preference when submitting your details; we will then NOT contact you again until you ask us to do so.

.

FT2 Turbine Flow Meter: Hall-Effect Detection: Order Codes

FT2 Turbine Flow Transducer

FT2 Turbine Flow Transducer

hall effect flow meter

e.g. 220-100-V-10-B is a flowmeter with a flow
range of 6.0 to 100 L/min, Viton® seal and 1' BSP
brass fittings with a standard 6 point traceable
water calibration.