Flowmeters: OG6 - 200 L/MIN OVAL GEAR METER features:
- Excellent chemical resistance
- Rugged construction
- Individual calibration
- High viscosity capability
- Low pressure loss
- No flow conditioning required
- Compact meter assembly
- Hall, reed or Namur sensor
- Accuracy
- 1.0% water
- 0.5% reading oil
- ±0.25% reading*
- 0.1% repeatability
- IP67/NEMA 4 protection
- Models to 400 Bar
- Non-metalic option
* When used with our metra-smart
Ideal for:
- Engine test
- Oil flow
- High viscosity fluids
- OEM equipment
- Hazardous areas
OG6 - 200 L/MIN OVAL GEAR FLOW METER
e.g. OG6-S S 5 - V H P-B is a standard flowmeter with a flow range of 10 to
200 L/Min, 316 stainless steel body, 50 Bar pressure rating, Viton seal, Hall effect detec-tor and 11/2”
BSP female fittings with a standard 6 point traceable water calibration.
OG6 - 200 L/MIN OVAL GEAR FLOW METER - Standard Materials of Construction
- Body and cap - 316 St St
- PEEK
- Aluminium
- ‘O’ Ring - Viton
- Gears - PEEK
- Magnets - Ceramic
|
OG6 - 200 L/MIN OVAL GEAR FLOW METER
|
The rugged OG6 oval gear flowmeter is designed to give high performance with a low cost of ownership. It has a standard flow range from 2 to 200 L/Min on 30 Cstk oil and 10 to 200 L/min on water like liquids. It can have totally non-metallic wet-ted components, PEEK™, ceramic and an elastomer which makes this the ideal choice for the metering of aggressive chemicals. The standard inlet and outlet are 3/4” BSP female threads. For OEM use alternatives, including manifold mount-ings, are available.
316 St St Body
|
Peek (TM) & Aluminium body
|
Flow range
Wetted materials
Standard pressure rating
Accuracy
Repeatability
Detector type
Terminations
Approximate 'K' factor - Pulse/L
|
- Water
- 30 cSt Oil
- Body
- Gears
- Seal
- Magnet
- Water
- 30 cSt oil
|
10 - 200 LPM
2 - 200 LPM
316 Stainless steel
PEEK™
Viton™
Ceramic
50 Bar
± 1.0 % Reading
± 0.5% Reading
± 0.1%
Hall effect
Cable Gland
70
|
4 - 100 LPM
0.5 - 100 LPM
Aluminium
PEEK™
Viton™
Ceramic
10 Bar
± 1.0 % Reading
± 0.5% Reading
± 0.1%
Hall effect
Cable Gland
70
|
|
At the heart of the meter are a pair of toothed oval gears one of which contains chemically resistant magnets, the gears rotate freely on robust bearings. Rotation is detected through the chamber wall by a Hall effect detector, Na-mur sensor or a reed switch giving approxi-mately 21 pulses per litre passed. The output is an NPN pulse or a voltage free contact closure either of which is readily interfaced with most electronic display or recording devices. This combination of materials and technology ensures a long life product with reliable, accurate operation throughout.
|
|
|
|
|