Titan Flowmeters: Metra batch - batch controller for flow meters
- High speed count
- Two stage control
- Automatic overrun compensation
- Simple programming with English prompts
- IP67 (Nema 4X)
- Remote start/stop facility
- Non volatile memory
- 8 Digit rate display
- 12-24V dc operation
- Batch total
- Accumulated total
- Number of batches total
- Networking facility
- Clear 9mm “starburst” LCD display
- Maximum dispense setting
- Received pulse time out
- Ideal for:
- Bottle filling
- Recipe blending
- Any batch process
Titan Flowmeters: Metra batch - batch controller for flow meters: Specification
Display
LCD 8 digit alpha-numeric 9mm
high Engineering units & mode
indicators 3 programmable decimal
points for both totalisers
English programming prompts
Signal inputs
Universal pulse-frequency input
compatible with reed switch, Hall
effect detector, magnetic coil
(20mV P-P), Voltage pulse & Namur
proximity detectors. Maximum
input frequency 500 to 5Khz de
pending on sensor type, minimum
0.2Hz,
Power
Internal 3.6V dc Ultra battery.
Life expectancy 5 - 7 years (less
with the coil input). An external
power supply (8-24Vdc regulated)
must be used .
Control output
Two selectable NPN or PNP field
effect transistors 1A maximum.
Enclosure
IP66 (NEMA 4X) High impact glass
reinforced nylon. Self drill cable
gland in the base or rear. Operat
ing temperature range –20°C to
+80°C.
K Factor range
0.001 to 9,999,999.999
Titan Flowmeters: Metra batch - batch controller for flow meters - Order codes
- Metra-batch: 380-102
- Wall bracket: 380-103
|
Titan Flowmeters: Metra batch - batch controller for flow meters
|
The Metra-batch was specifically designed for flowmeters
or machinery with pulse or frequency outputs. It has a two
stage batching facility with selectable automatic over-run
compensation as well as safety features to prevent erroneous
dispense with a faulty system. Batching can be set to
either count up from zero or down from the batch quantity
as well as programmed for local, remote, automatic or
manual start. Simple PIN protected flow chart programming
with English prompts guide you through the entire set
up routine greatly reducing the need to refer to the instruction
manual. Several Metra-batches may be used in conjunction
with each other with lock out and networking enunciation
giving the user full operating data. The robust
housing is purposed designed to suit harsh indoor & outdoor
industrial environments. It is weatherproof to P67
(Nema 4X) standards, UV resistant and uses glass reinforced
nylon mouldings with stainless steel screws & viton
0-ring seals.
Titan Flowmeters: Metra batch - batch controller for flow meters - simple programming
Program mode entered: Display self tests
Enter PIN number: XXXX
Change PIN number Y/N: Incorrect PIN number permits viewing of the program data only
Reset ACCUM total: Y/N
Set engineering units: Ltr, gal, M3, lbs, kgs or none
Enter pulses per unit volume: E.g. 20.465 Pulses per litre etc.
Set decimal point Dpt TOTAL | Dpt ACCUM TOTAL: 0 0.0 0.00 0.000 | 0 0.0 0.00 0.000
Set count direction: Count DN/up
Start delay relay 2: 000 - 999 seconds
Pre stop valve - relay 2: 000 - 999 seconds
Automatic overrun compensation: Y/n
Set missing pulse time out: 00 - 99 seconds
Set batch limit: xxxxxxxx
Titan Flowmeters: Metra batch - batch controller for flow meters - simple batch operating procedure
Press BATCH SET
Enter batch quantity xxxxxxxx
Press BATCH SET
Press RUN…...to pause press STOP
to abort press RESET
to resume press RUN
End of batch
|
|
|