Rate and Totalising Turbine Flow meter – Instructions

rate and totalising turbine flow meter with display

e.g. 865-V O P-O-Disp is a flow range of 0.25
to 6.5 L/min, VitonTM seal, standard, PVDF
bodied flowmeter with a 6 point traceable water
calibration.

Overview of 800 Series Displaying Turbine Flow Meter Installation

The principle of operation is very simple. A jet of liquid is directed at a free running Pelton wheel turbine in a specially shaped chamber. The rotation of the rotor is detected with a Hall effect sensor. The output frequency of these pulses is directly proportional to flow rate and the total number of pulses the total volume passed. The bearing material is sapphire as this gives a long trouble free life to the meter. The non-metallic construction means that these meters may be used with aggressive chemicals and ultra-pure water. Very strong acids will damage the ceramic magnet.

Installation of the 800 Series Rate, Totalsing & Displaying Flow Meter

The meter produces a pulse output the frequency of which is proportional to the flow through the device.

  • Suitable for many liquids including water and most fuels
  • Connections for 8mm dia. hoses or 3/8” John Guest
  • Reliable and accurate
  • Supplied with 2M (approx) of cable.
  • Flow ranges from 50 mL/Min to 15 L/Min.

Note: when used in automotive applications, the formation of vapour should be minimised by fitting the sensor between the fuel pump and the carburettor, but before any pressure regulator. The device should be mounted vertically if vapour is likely to form.

The pipe work must be designed in such a way as to eliminate reverse flow, and the liquid pass through the meter in the direction of the arrow. The meter should be installed in a position that prevents it from draining down as on start-up serious damage could result by “impacting” an empty flowmeter with a high velocity fluid stream. The fluid should be clean and homogenous. In all cases an upstream filter of at least 80 microns must be fitted. It is recommended that before the flowmeter is installed in the line a “dummy” section of pipe is inserted and the system flushed. This is to eliminate any debris in that section of the line. The pipe must not stress the body of the meter and should be fully supported either side with appropriate isolation valves and in some cases a by-pass valve. On initial start-up increase the flow slowly to ensure no over speeding of the meter occurs as the air is forced from the line. This is best achieved by monitoring the flow rate and ensuring that a 50% over-range is not exceeded. Never blow a flowmeter with an airline. Care should be taken to ensure that no air enters the system (e.g. leaky pump gland) or that no cavitation takes place. With a volatile liquid we recommend at least twice the vapour pressure plus 1 Bar as the operating pressure. The user must ensure that the materials of construction are compatible with their fluid. We accept no responsibility for material compatibility; it is the users’ responsibility.

Inserting a Ranging Jet for the 800 Series Displaying Flow Meter

There are four ranging jets that may be inserted into the inlet to alter the flow capacity of the meter. Once a jet is inserted it cannot be easily removed without damaging it or the flowmeter bearings. Care should be taken in selecting the correct jet as more than one may not be used. Consider the chart on page 2 and select what flow range is required at what pressure drop, more than one flowmeter may be suitable for the flow rate. For best accuracy choose the jet that has the highest permissible pressure drop as the meter performance will generally be better than a jet with the lowest pressure drop. Use a large diameter punch between 5.5mm and 6mm and drive the jet firmly home until it hits a stop.

Once any jet is fitted the original calibration is void.

turbine flow meter with rate and total display

800 Series Displaying Turbine Flow Meter Pressure vs Flow

800D displaying flowmeter specification

 

displaying flow meter rate and total

It is recommended that all “signal” cables are run separately to
power lines and switched inductive loads and are located well
away from inverters and other “noisy” apparatus. Always use
sound wiring practice.

Jet Flow
L/Min
Linearity
% FSD
Typical FS
Freq. Hz.
Approx
‘K’Factor
803 0·05 – 0·5 2.0 142 17000
815 0·05 – 1·5 2.0 175 7000
845 0·15 – 4·5 1.5 260 3500
865 0·18 – 6·5 1.5 230 2100
810 0·20 – 10.0 1.0 235 1420
824 0.50 – 15.0 1.0 245 980
F.S. Pressure drop 1 Bar @ 1cSt
Working pressure 10 Bar
Temperature range body -25 to +125 °C, 0 to 60°C Display
Repeatability ±0.25%
Sensor to sensor variation ±5%
Supply voltage 8 to 12 V dc.
Current consumption 40 mA (typical)
Outputs 5v pulse
Output low 100mV max.
Rise & fall times 2uS max
Wetted materials PVDF, sapphire & VitonTM. Ceramic magnet
Weight 0.081kg

Displaying 800 Series flow turbine meter – Electrical characteristics

Hall effect sensor

Supply: 8 – 12Vdc
Temp range: -10 to 55°C
Rise & fall times: 1.5uS max
Supply current: 80mA typ

Displaying 800 Series flow turbine meter – Commissioning

If problems occur during commissioning always check the fundamentals first.

  • Is the flowmeter/instrument the correct one for the installation?
  • Is the power connected to the meter and the instrument, and is it turned on?
  • Is the instrument set/wired correctly? I/P port, pulse type, frequency span, units etc.
  • Where possible check the O/P from the flowmeter with an oscilloscope before proceeding
  • Was the line flushed prior to installing the meter?
  • Was the flow increased slowly?
  • Is the meter blocked?

If you cannot find a solution ask your supplier for technical support

 

Programming the 800 D Flowmeter

 

Buttons/Display Description
800-Displaying-Turbine-Flowmeter-p1 In normal operation when the meter is showing flow rate the “colon” in the centre flashes.
The “unit” and time base are independently determined in the calibration routine,
e.g. cc/sec, grams/minute, litres/Hour etc. If “both” is selected in the menu the left hand button will change the display to total and then
back to rate. The right hand button can be selected to reset the totaliser. The “unit” is the
same as the rate meter but the decimal point position may differ.
800-Displaying-Turbine-Flowmeter-p2 If both buttons are pressed together for four seconds the meter enters program mode and a
request is made to enter a PIN. The display flashes between the two words “Pin” & “no”. If
no PIN has been entered a press of the left key will advance the program to the next step.
The default PIN is 0000. If a PIN is required the display changes with the left hand digit flashing zero. The right hand
button increments the number, when the required number is reached the left hand button
moves the flashing digit to the right. Each digit or location can be cycled until the number
you require is reached. Holding the left hand button for 3 seconds then enters the PIN
chosen and advances the program. To exit the programming at any time press both keys
together for 4secs.
800-Displaying-Turbine-Flowmeter-p3 This gives the option of changing the PIN. The left key by-passes this option. If the right key
is pressed the existing PIN will be displayed. The method of changing the display is as
above with the right hand key changing the number and the left hand key changing the digit
being altered. A three second press and hold on the left hand key advances the program.
800-Displaying-Turbine-Flowmeter-p4 This function allows the user to self calibrate the indicator by passing a pre-determined
amount through the flowmeter. The electronics records the number of pulses received,
calculates the pulses per “unit” as the ‘K’ factor and enters it in the “SCL Fact” section later in
the programming. This number may be edited later if required. Any “unit” may be used,
grams, cc, litres etc. This “unit” is used for both total & rate displays. The right hand key
enters the volume selection routine & increments the required amount of liquid through preset
values, 0.1 0.25 0.5 1.0 5.0 10 & 20. Before this program is continued the flowmeter
must be primed and ready to discharge the pre-set amount. The larger the amount the more
accurate the calibration. When the left hand key is pressed the internal counter counts the
number of pulses received until the counter is stopped. The display shows “run” until no
further pulses are received or the left button pressed (e.g. against a measuring cylinder) and
then it shows “stop” to show the count is completed. To proceed press the left key.
800-Displaying-Turbine-Flowmeter-p5 This function permits the user to select the display function, three options are available.
When the right key is pressed the display changes to the previously selected option. Further
presses of the key cycle through the options, flow rate only “rate”, totaliser only “tot” and
switchable between rate and total “both” using the left hand key in the run mode. The right
key cycles the options and the left hand one advances the program to the next section.
800-Displaying-Turbine-Flowmeter-p6 This sets the decimal place for the totaliser. When the right key is pressed the display
changes to the previously set position, repeated presses cycles the display through the
options 0000 000.0 00.00 & 0.000. These are decimals of the chosen “unit”. The left
hand key advances the program.
800-Displaying-Turbine-Flowmeter-p7 The scale factor is the number of pulses for a given unit of liquid, the chart on the front page
gives a starting point for pulses per litre but any convenient measurement can be used.
These figures are only approximate and will vary from meter to meter and the system into
which it is installed. In all cases it is best to calibrate the meter in the actual running
conditions. If “Auto cal” has been used the ‘K’ factor that the electronics calculated will be
displayed. As the number of pulses per unit may be greater than 9999 the actual number is
entered in two sections permitting a factor of 99999.9. First tens of thousands and then
thousands the remaining digits – hundreds, tens, units and tenths are entered in the
calibration section “rest”. The right hand key begins the entry mode, it then cycles the
number and the left hand key moves to the next digit. Holding the left key for 3 seconds
advances the program to “set rest”.
800-Displaying-Turbine-Flowmeter-p8 This section sets the three least significant digits and a decimal place. The right hand key
changes the display and the left hand digit flashes to show it is in entry mode. Further
presses of the right key cycles through the digits 0 to 9, the left hand key advances the entry
option to the next digit. When the required number has been entered press the left key for
3 seconds to advance to the next section.
800-Displaying-Turbine-Flowmeter-p9 If either “tot” or “both” mode is selected in the “disp sel” section of the program the user has
the option to disable the totaliser reset button. “Yes” means the reset button works, “no”
disables it. Pressing the right hand button the display shows the previously selected state,
either yes or no. Pressing the right hand key changes the display the left hand key
acknowledges the choice and advances the program. Changing the choice from no to yes
will not reset the counter until the right hand key is pressed in run mode.
800-Displaying-Turbine-Flowmeter-p10 The “rate dp” is the number of decimal places required for the flow rate indicator. The right
key changes the display to the previously selected value.
Further presses will cycle the display through the available options. 0000 000.0 00.00 &
0.000 Pressing the left key uses the selected option when ever flow rate is being displayed.
800-Displaying-Turbine-Flowmeter-p11 “Rate” is the time base used for flow rate display, e.g. unit volume per second, per minute
or per hour. The right key enters the mode and cycles between the options “SEC”, “60 S”,
“hour”. The left key enters the option and advances the program step.
800-Displaying-Turbine-Flowmeter-p12 This option permits the user to alter the degree of filtration on the display, 0 is no filtering
and 9 is the maximum. This does not affect the totaliser just the amount the display “jitters”
during normal operation and its response to step changes in flow rate. The right key enters
the mode and cycles the number; the left key enters the option and exits the program. The
word “End” shows for approximately 2 seconds before the unit returns to the “run” mode.
Note: – not all display options are possible and an error may occur if the device is operating at
the extremes of the internal arithmetic. If an error occurs re-calibrate the electronics increasing
or decreasing the resolution or alter the time base.